Building a strong radiation safety culture starts with giving the medical staff real-time insight about their personal exposure. DoseAware is an active dosimetry system that provides real-time insights about radiation exposure, helping medical staff and physicians evaluate and directly adjust their behaviors.

Kontaktné informácie

* Toto pole je povinné

Kontaktné údaje

*
*
*

Detaily spoločnosti

*
*
*
*
*
*
*

Obchodné podrobnosti

Upresnením vášho dôvodu kontaktu Vám budeme môcť poskytnúť lepšiu službu.
*
*

Specifications Show all

Personal Dose Meter
Weight
30 grams (1.06 ounces)
Operational unit
30 grams (1.06 ounces)
X-ray dose range
1 μSv – 10 Sv
X-ray dose resolution
1 μSv
X-ray dose uncertainty
5% or 1 μSv
X-ray dose rate range and linearity
+/- 10% 40 μSv/h – 150 mSv/h
+/- 20% 150 mSv/h – 300 mSv/h
Energy dependency rays
N40-N120 (33 keV – 101 keV)
Average battery life
3 – 5 years, depending on daily use
DoseAware Xtend Hub (to be mounted on ceiling)
Dimensions
13.5 x 18.5 x 3.5 cm (w x h x d) / 5.3 x 7.3 x 1.4 inch
Weight
170 grams (6 ounces)
Display
via FlexVision XL
Resolution
640 x 480 pixels
Storage
All X-ray dose-rate/sec and accumulated X-ray dose/hr that are received from PDMs in range.
For example: the memory size accommodates 250 PDMs with 50 hours X-ray dose rate history each.
Communication
Wireless radio communication with PDMs (868,3 918,3 927,9 MHz)
Ethernet
10/100 Mbits/s port for the Dose Manager and connection to X-ray system.
DoseAware Xtend reporting
Email reports
By week or by month, by PDM or by lab
Operator RDSR
Comprehensive Structured Report, up to 3 SCP can be configured as receivers.
Operator RDSR SOP class
UID 1.2.840.10008.5.1.4.1.1.88.33
DoseAware Base Station
Dimensions
30 x 25 x 6 cm (w x h x d) / 11.8 x 9.8 x 2.4 inch
Weight
1.45 kilograms (51.15 ounces)
Display
10.4 inch touch screen
Resolution
640 x 480 pixels
Storage
All X-ray dose-rate/sec and accumulated X-ray dose/hr that are received from PDMs in range.
For example: the memory size accommodates 250 PDMs with 50 hours X-ray dose rate history each.
Communication
Wireless radio communication with PDMs (868,3 918,3 927,9 MHz)
Ethernet
10/100 Mbits/s port for the Dose Manager connection
Dose Manager (PC requirements)
Operation system
Windows XP, Vista or Windows 7
System memory
At least 2 GB
Hard disk
40 GB with at least 15 GB available space - USB 2.0 port
DoseView (PC requirements)
Operation System
Windows XP, Vista or Windows 7
System memory
At least 1 GB - USB 2.0 port