Patient Monitoring

Specifications

Physical specifications
Physical specifications
Width
  • 33 cm (not to exceed)
Height
  • 23 cm (not to exceed)
Depth
  • 23 cm (not to exceed)
Weight (fully options, with battery)
  • 5 kg or less
Battery, lithium ion, smart battery
  • 11.1 V, 7800 mAh
Battery operating time (new, fully charged)
  • At least 6 hours
Internal power supply
  • 100 to 240 VAC
Maximum output power consumption
  • 60 W
Frequency
  • 50/60 Hz
Display
Display
Screen type
  • LCD with 5-wire resistive touchscreen
Screen size
  • 10.1 in
Refresh frequency
  • 60 Hz
Resolution
  • 216.96 x 135.6 mm
Viewing angle
  • ±85°
Recorder
Recorder
Type
  • Thermal
Paper width
  • 58 mm
User selectable speeds
  • 6.25, 12.5, 25, 50 mm/sec
Environmental specifications
Environmental specifications
Humidity, operating and storage for monitor
  • 10% to 90% of RH (non-condensing)
Humidity, operating and storage for monitor with recorder and paper
  • 10% to 90% of RH
Noninvasive blood pressure measurement
Noninvasive blood pressure measurement
Adult systolic range
  • 30 to 270 mmHg
Adult pulse rate range
  • 40 to 300 bpm
Pediatric systolic range
  • 30 to 180 mmHg
Pediatric pulse rate range
  • 40 to 300 bpm
Neonatal systolic range
  • 30 to 130 mmHg
Neonatal pulse rate range
  • 40 to 300 bpm
NBP interval choices
  • Off, 1, 2, 3, 5, 10, 15, 30, 60, 90, or 120 minutes or STAT
CO2 measurement
CO2 measurement
Measurement range
  • 0-150 mmHg
Physical specifications
Physical specifications
Width
  • 33 cm (not to exceed)
Height
  • 23 cm (not to exceed)
Display
Display
Screen type
  • LCD with 5-wire resistive touchscreen
Screen size
  • 10.1 in
See all specifications
Physical specifications
Physical specifications
Width
  • 33 cm (not to exceed)
Height
  • 23 cm (not to exceed)
Depth
  • 23 cm (not to exceed)
Weight (fully options, with battery)
  • 5 kg or less
Battery, lithium ion, smart battery
  • 11.1 V, 7800 mAh
Battery operating time (new, fully charged)
  • At least 6 hours
Internal power supply
  • 100 to 240 VAC
Maximum output power consumption
  • 60 W
Frequency
  • 50/60 Hz
Display
Display
Screen type
  • LCD with 5-wire resistive touchscreen
Screen size
  • 10.1 in
Refresh frequency
  • 60 Hz
Resolution
  • 216.96 x 135.6 mm
Viewing angle
  • ±85°
Recorder
Recorder
Type
  • Thermal
Paper width
  • 58 mm
User selectable speeds
  • 6.25, 12.5, 25, 50 mm/sec
Environmental specifications
Environmental specifications
Humidity, operating and storage for monitor
  • 10% to 90% of RH (non-condensing)
Humidity, operating and storage for monitor with recorder and paper
  • 10% to 90% of RH
Noninvasive blood pressure measurement
Noninvasive blood pressure measurement
Adult systolic range
  • 30 to 270 mmHg
Adult pulse rate range
  • 40 to 300 bpm
Pediatric systolic range
  • 30 to 180 mmHg
Pediatric pulse rate range
  • 40 to 300 bpm
Neonatal systolic range
  • 30 to 130 mmHg
Neonatal pulse rate range
  • 40 to 300 bpm
NBP interval choices
  • Off, 1, 2, 3, 5, 10, 15, 30, 60, 90, or 120 minutes or STAT
CO2 measurement
CO2 measurement
Measurement range
  • 0-150 mmHg
  • Product may not be available in all geographies, please check with your Philips representative for complete portfolio availability.

You are about to visit a Philips global content page

Continue

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.

Vstupujete na slovenskú webovú stránku Philips Healthcare.
Please select the checkbox

Webová stránka je určená len pre osoby, ktoré používajú zdravodntícke pomôcky ako profesionáli, vrátane zdravotníckych pracovníkov, osôb konajúcich za poskytovateľov zdravotnej starostlivosti alebo za obchodníkov so zdravotníckymi pomôckami.

Ste osoba, ktorá spĺňa vyššie uvedené kritériá?